2 x Temperature IN
CANopen / CANopen FD / J1939 Transmitter for Temperature Measurement
µCAN.2.ti-TRS
The cable transmitter µCAN.2.ti-TRS is designed for the acquisition of two temperature signals and their digitization for being processed via CAN bus. The TRS module is integrated directly in the measurement line at a short distance from the source to avoid interference effectively.
Features
- Temperature Pt100, Pt1000 (2-wire)
- Accuracy ± 0.2 K (Pt100)
- Resolution 16-bit (0.1 °C)
- Sampling rate up to 1 kHz
- Sensor error detection
- Equipped with cold-junction compensation
- Fieldbus CAN Classic / CAN FD
- Protocol CANopen / CANopen FD / J1939
Variants
The 2-channel TRS module is available in different variants.
Please contact us of more information and customized solutions.
Further designs
µCAN.1.ti-BOX
1-channel analogue input temperature
µCAN.4.ti-BOX
4-channel analogue input temperature
µCAN.1.ti-SNAP
1-channel analogue input temperature
µCAN.8.ti-SNAP
8-channel analogue input temperature
µCAN.16.ti-19" / thermocouple
16-channel analogue input temperature
µCAN.16.ti-19" / RTD
16-channel analogue input temperature
µCAN.4.ti-F1 / thermocouples
4-channel analogue input temperature
µCAN.4.ti-F1 / Pt100
4-channel analogue input temperature
µCAN.1.ti-TRS
1-channel analogue input temperature
µCAN.1.ti-SENSOR
1-channel analogue input temperature
µCAN.2.ti-SENSOR
2-channel analogue input temperature
µCAN.1.ti-BOX
1-channel analogue input temperature
µCAN.4.ti-BOX
4-channel analogue input temperature
µCAN.16.ti-19" / thermocouple
16-channel analogue input temperature
µCAN.16.ti-19" / RTD
16-channel analogue input temperature
µCAN.1.ti-SNAP
1-channel analogue input temperature
µCAN.8.ti-SNAP
8-channel analogue input temperature
µCAN.4.ti-F1 / thermocouples
4-channel analogue input temperature
µCAN.4.ti-F1 / Pt100
4-channel analogue input temperature
µCAN.1.ti-SENSOR
1-channel analogue input temperature
Ordering information
2-channel temperature acquisition module. Signal type Pt100. Connection via M12x1 circular connector. Fieldbus: CAN / CAN FD. Protocols: CANopen / CANopen FD / J1939
2-channel temperature acquisition module. Signal type Pt1000. Connection via M12x1 circular connector. Fieldbus: CAN / CAN FD. Protocols: CANopen / CANopen FD / J1939
Downloads
Datasheet µCAN.2.ti-TRS
2-channel analogue input temperature
PDF [702 KB]
Quickstart Manual TRS
2-channel analogue input temperature
PDF [109 KB]
Manual µCAN.2.ti-TRS
2-channel analogue input temperature
PDF [1.16 MB]
EDS-file
mcan2xi_sensor_v1r02.eds
EDS [49 KB]
Application Note AN1204
Setting of module ID and bit rate via LSS
PDF [204 KB]
Application Note AN5005
Multi-Protocol Devices
PDF [396 KB]
Handout Sensor Connection
PDF [88 KB]
Order a Sample
Get a
sample module!
Any questions?
+49 2241 – 25 65 9 – 0
Write an email or give us a call.