2 x Temperature IN

CAN / CANopen / J1939 Sensor acquisition for temperature sensors

µCAN.2.ti-SENSOR

µCAN-SENSOR board
Home 9 Portfolio 9 I/O Modules 9 OEM 9 µCAN.2.ti-SENSOR

The sensor module µCAN.2.ti-SENSOR can be joined to any sensor and is designed to acquire two analogue temperature signals. It can be integrated directly in the sensor head (18 mm in diameter). Sensor tolerances can be adjusted. The sensor signals are linearized and monitored directly in the hardware.

Logo ZIM project
Sensor board front and back

Precise temperature measurement in the sensor: µCAN.2.ti-SENSOR

Features

  • Temperature Thermo type J, K, L
  • Temperature Pt100, Pt1000 (2-wire)
  • Accuracy ± 0,5 K (Thermo)
  • Accuracy ± 0,2 K (Pt100)
  • Resolution up to 16 Bit (0.1 K)
  • Sampling rate up to 1 kHz
  • Signal type freely configurable
  • Sampling rate adjustable
  • Operating temperature -40 °C to +85 °C
  • Supply voltage 9 V DC to 36 V DC
  • Fieldbus CAN Classic / CAN FD
  • Protocol CANopen / CANopen FD / J1939

    Variants

    The 2-channel OEM module is available in different variants. Please contact us of more information and customized solutions.

    Further designs

    Ordering information

    Item no.
    Description
    13.70.001
    µCAN.2.ti-SENSOR / Thermo type J

    2-channel sensor acquisition module. Signal type thermocouple type J. Connection by through-hole-technology (THT) in a 2.54 mm grid. Fieldbus: CAN / CAN FD. Protocols: CANopen / CANopen FD / J1939

    13.71.001
    µCAN.2.ti-SENSOR / Thermo type K

    2-channel sensor acquisition module. Signal type thermocouple type K. Connection by through-hole-technology (THT) in a 2.54 mm grid. Fieldbus: CAN / CAN FD. Protocols: CANopen / CANopen FD / J1939

    13.72.001
    µCAN.2.ti-SENSOR / Thermo type L

    2-channel sensor acquisition module. Signal type thermocouple typ L. Connection by through-hole-technology (THT) in a 2.54 mm grid. Fieldbus: CAN / CAN FD. Protocols: CANopen / CANopen FD / J1939

    13.80.001
    µCAN.2.ti-SENSOR / Pt100

    2-channel sensor acquisition module. Signal type Pt100. Connection by through-hole-technology (THT) in a 2.54 mm grid. Fieldbus: CAN / CAN FD. Protocols: CANopen / CANopen FD / J1939

    13.81.001
    µCAN.2.ti-SENSOR / Pt1000

    2-channel sensor acquisition module. Signal type Pt1000. Connection by through-hole-technology (THT) in a 2.54 mm grid. Fieldbus: CAN / CAN FD. Protocols: CANopen / CANopen FD / J1939

    Downloads

    Datasheet µCAN.2.ti-SENSOR
    2-channel analogue input temperature
    PDF [716 KB]

    EDS-file
    mcan2xi_sensor_v1r02.eds
    PDF [49 KB]

    Application Note AN5005
    Multi-Protocol Devices
    PDF [396 KB]

    Handout Sensor Connection
    PDF [88 KB]

    Order a Sample

    Get a

    sample module!

    Any questions?

    +49 2241 – 25 65 9 – 0

    Write an email or give us a call.